Introduction
The 16 kWh wall-mounted residential energy storage system is designed for solar-plus-storage, whole-home backup, and time-of-use energy management. Its slim tower design supports wall or floor installation in homes and garages, powering loads such as air conditioners, heat pumps, water heaters, and EV chargers.
Technical Specifications
|
Parameter |
Specification |
|
Rated Energy |
16.07 kWh |
|
Usable Energy |
14.46 kWh @ 90% DoD |
|
Nominal Voltage |
51.2V DC |
|
Operating Voltage |
48.0–57.6V DC |
|
Rated Capacity |
314Ah |
|
Battery Cells |
16S1P LiFePO4, 3.2V / 314Ah |
|
Max. Charge Current |
150A |
|
Max. Discharge Current |
150A |
|
Recommended DoD |
90% |
|
Cycle Life |
6,000+ cycles @ 80% DoD, 25°C |
|
Dimensions (W×H×D) |
650 × 1100 × 285 mm |
|
Weight |
Approx. 115 kg |
|
Mounting |
Wall-mounted; floor stand optional |
|
Wall Requirements |
Concrete, solid brick, or structural steel; >150 kg |
|
Clearance |
300 mm top/bottom; 150 mm sides |
|
Operating Temperature |
Charge: 0–45°C; Discharge: -20–55°C |
|
Storage Temperature |
-10–35°C |
|
Humidity |
5–95% RH, non-condensing |
|
Protection Rating |
IP54 |
|
Cooling / Noise |
Natural convection / <40 dB at 1 m |
Backup Power Performance
Emergency Backup Operation: Backup power switchover speed (< 10 ms) and output limits are determined by the connected hybrid inverter.
Inductive Load Handling: Support for motor loads depends on the connected inverter's peak surge rating and the battery's maximum continuous discharge current (150A).
Capacity Sizing: System sizing depends on continuous load demands, peak starting currents, inverter continuous output limits, and required backup duration.
Inverter Compatibility
|
Item |
Specification |
|
Compatible Inverters |
Deye, GoodWe, Sungrow, Victron Energy |
|
Models |
SUN-5/6/8/10/12K-SG04LP3; GW5000/6000-ES-20; SH5.0/6.0RS; MultiPlus-II/Quattro 48V |
|
Communication |
CAN / RS485 / RS232 |
|
Ports |
Dual RJ45 |
|
Protocol |
Configurable via IPS display or DIP switch |
|
Accessories |
2m CAN/RS485 cable, M10 terminals |
Protection Architecture
Overcharge & Over-Discharge Protection: BMS disconnects the charge circuit if cell voltage exceeds safe limits (>3.65V) and cuts the discharge circuit if cell voltage drops below operational limits (<2.5V).
Over-Current & Short-Circuit Protection: Electronic current limiting backed by hardware fuse isolation to protect against short-circuit events.
Thermal Protection: Multi-point internal temperature sensors actively limit or disconnect charge/discharge current when temperatures fall outside specified thresholds.
Cell Balancing: Passive balancing circuit aligns cell voltages during the upper charging stage.
Thermal Protection & Isolation: Internal flame-retardant barriers, physical cell separation, and automatic hardware isolation logic.
System Scalability
Maximum Expansion: Supports parallel connection of up to 6 identical battery units.
Communication Setup: DIP switch addressing establishes Master/Slave relationships via standard RJ45 patch cables.
Pre-Expansion Requirements: Parallel units must run identical firmware versions and be voltage-matched (within 0.5V difference) before busbar connection.
Combiner Hardware: Systems utilizing 3 or more parallel units require an external DC combiner box to manage aggregate output currents.
Quality Assurance
Cell Screening: 100% of incoming LiFePO₄ cells are tested and matched for open-circuit voltage, internal resistance, and capacity before assembly.
Busbar Joining: Laser-welded busbars undergo visual and electrical integrity checks under load.
Electrical Safety: Battery packs receive high-voltage insulation and Hi-Pot testing between live circuits and the grounded enclosure.
BMS Verification: BMS protection, cell balancing, and communication functions are fully tested.
Aging Test: Completed units undergo a 72-hour charge/discharge burn-in under simulated loads before final inspection and packaging.
FAQ
Q: What are the MOQ, lead time, and compatibility terms?
A: MOQ is five stock units or one to two samples. Stock ships in 10–15 days. Compatibility depends on the inverter model, not order volume.
Q: How many units fit on a pallet or in a container?
A: A pallet holds six units; a 40HQ holds approximately 140.
Q: Are samples available?
A: Yes. One to two samples ship within 5–7 days and are credited against orders of at least 20 units.
Q: Is the DC combiner included?
A: No. It is a separate item required for systems with three or more parallel units.
Q: Does 90% DoD affect cycle life?
A: Yes. The 6,000-cycle rating is based on 80% DoD. For longer service life, use approximately 80% DoD and allow a full charge weekly.
Q: How should passive balancing be maintained?
A: Allow the battery to reach 100% SOC approximately once a week to help correct cell drift.
Q: What certifications and compliance documents are available?
A: The battery is CE-marked and complies with the EU RoHS Directive (2011/65/EU). It is certified to IEC 62619 for stationary and industrial energy-storage safety and to UN 38.3 for lithium-battery transport. IEC 62619 certificates/test reports, MSDS, and UN transport documents are available upon request.
Hot Tags: 16kwh wall mount home battery | residential solar backup power system, China 16kwh wall mount home battery | residential solar backup power system manufacturers, suppliers, factory