Battery Energy Storage Systems for Commercial and Industrial Applications
Commercial and industrial energy storage systems (C&I BESS) store electricity from the grid or on-site renewable generation for peak shaving, load shifting, backup power, and renewable energy integration. Available in cabinet and containerized configurations, these systems combine LFP batteries, PCS, BMS, thermal management, fire protection, and EMS for commercial and industrial energy storage projects.
Product Specifications
|
Product Parameter |
Specification |
|
Battery Chemistry |
LiFePO4 (LFP) Prismatic |
|
Capacity Range |
241 kWh – 1,075 kWh |
|
Rated Power |
100 kW – 500 kW |
|
Available Models |
GSC-M-241A / GSC-M-261A / GSC-L-261L / Containerized System |
|
Cooling System |
Forced Air / Closed-Loop Liquid Cooling |
|
Enclosure Type |
Outdoor Cabinet / 20ft ISO Container |
|
DC Voltage Range |
672 – 864 VDC |
|
Grid Voltage |
400 / 480 VAC |
|
Grid Frequency |
50 / 60 Hz |
|
Power Factor |
0.8 Lagging – 0.8 Leading |
|
Cycle Life |
≥6,000 cycles |
|
Cycle Test Condition |
0.5C Charge/Discharge, 25°C |
|
EOL Capacity |
70% SOH |
|
Operating Temperature |
-20°C to +50°C |
|
Charging Temperature |
0°C to +45°C |
|
Storage Temperature |
-20°C to +45°C |
|
Enclosure Protection |
IP55 |
|
Altitude |
Up to 2,000 m without derating |
|
Corrosion Protection |
C3 Standard / C5 Optional |
|
AC-to-AC RTE |
≥87.5% including auxiliary HVAC loads |
Target Applications
Factory Load Management
Reduces peak demand charges via scheduled peak shaving and load shifting.
01
Commercial Building Optimization
Minimizes utility costs through Time-of-Use (TOU) tariff arbitrage.
02
Solar PV Integration
Stores excess solar generation to maximize site energy self-consumption.
03
EV Charger Buffering
Mitigates grid impact during high-power EV charging demands.
04
Industrial Microgrids
Delivers backup power and grid stabilization in off-grid or weak-grid environments.
05
System Control Architecture
Control Architecture
4-tier hardware and software hierarchy comprising BMU (Cell Level) → RBMS (Rack Level) → SBMS (System Level) → EMS (Plant Level)
Communication Interfaces
CAN, Modbus RTU, and Modbus TCP for BMS, PCS, EMS, and SCADA integration, subject to interface compatibility.
Operational Control Interfaces
Local touch-screen display panel combined with secure remote monitoring options.
Peak Shaving: Automatically limits grid import during predefined peak-demand periods.
Load Shifting: Charges during lower-cost periods and discharges during higher-cost periods.
PV Self-Consumption: Stores excess solar generation and supplies stored energy during periods of low PV output.
Backup Power: Provides backup power to designated loads when configured with the required grid isolation and control equipment.
Grid-Forming / Microgrid Operation: Available on applicable configurations, subject to PCS, EMS, and site-level system design.

Multi-Stage Safety: Cell and system-level monitoring, fault detection, electrical isolation, thermal management, and fire suppression are integrated according to the system configuration.
Hazard Detection: Available detection devices may include temperature, smoke, combustible gas, CO, H₂, and aerosol sensors, depending on system configuration.
Electrical Isolation
Automated high-speed DC circuit breakers triggered via BMS/EMS safety logic.
Thermal Mitigation
Cell-to-cell thermal barriers combined with targeted thermal management controls.
Fire Suppression System
FK-5-1-12 clean-agent or aerosol-based fire suppression is available depending on system configuration and project requirements.

Cabinet Unit (241 kWh / 261 kWh): Dimensions 1,400 × 1,200 × 2,300 mm | Approximate weight: 2,800 kg | Maintenance clearances: Front ≥ 1,200 mm, Rear ≥ 1,000 mm, Side ≥ 800 mm
Containerized Unit (1,075 kWh): Dimensions 6,058 × 2,438 × 2,591 mm (20ft ISO) | Approximate weight 14,000 kg | Maintenance clearances: Front ≥ 1,500 mm, Rear ≥ 1,500 mm, Side ≥ 1,200 mm
Final foundation, clearance, lifting, fire-access, and electrical requirements should be confirmed against the selected model and local codes before installation.
Multi-Unit Parallel Scalability
System Expansion
Connect up to 10 cabinet units in parallel under a master EMS architecture.
Maximum Cabinet Capacity
Provides up to 2.61 MWh total capacity and 1.25 MW rated power output using GSC-L-261L units.
Quality Control
Incoming Inspection
Battery cells and key electrical components are inspected against defined specifications before assembly.
Battery Assembly
Cells, modules, racks, BMS units, and electrical connections are assembled and inspected in accordance with established production procedures.
System Testing
BMS, PCS, and EMS communications, as well as protection functions, alarms, and system controls, are thoroughly tested before shipment.
Final Inspection
Electrical and mechanical systems, labeling, documentation, and packaging are inspected before delivery.
Scope of Supply
Standard Package Deliverables: Enclosure cabinet/container, LFP battery racks with tiered BMS, Power Conversion System (PCS), thermal management system, fire suppression setup, local EMS interface, and internal protection/cabling.
Optional System Add-ons: Step-up isolation transformers, microgrid control integration modules, external AC distribution panels, and multi-year on-site service packages.
|
Item |
Information |
|
MOQ |
1 system |
|
Standard Lead Time |
8–12 weeks |
|
Customization |
OEM/ODM available |
|
Shipping Terms |
EXW / FOB / CIF / DDP |
|
Inspection |
Factory / Third-party inspection available |
Warranty
Core Hardware Warranty
5-year standard warranty on battery modules and Power Conversion Systems (PCS).
Auxiliary Systems Warranty
2-year standard warranty covering BMS, EMS, and thermal management hardware.
Operational Capacity Guarantee
70% usable capacity retention guaranteed up to 5 years or 3,000 equivalent full cycles, subject to operation within standard contract parameters.