Household Inverters for Residential Solar & Energy Storage Systems
Household inverters convert DC power from solar PV arrays or batteries into AC power for residential loads. The product range covers grid-tied, hybrid, AC-coupled, and off-grid configurations for residential solar, energy storage, backup power, and retrofit applications.
Product Range
|
Series |
Power Range |
Phase Configuration |
System Type |
Battery Compatibility |
Typical Application |
|
VT-RGT Series |
1 kW – 20 kW |
Single-Phase / Three-Phase |
On-Grid (Grid-Tied) |
Not Applicable |
Grid-tied residential solar arrays |
|
VT-RHB-LV Series |
3.6 kW – 12 kW |
Single-Phase |
Hybrid |
Low-Voltage (48V LiFePO4 / Lead-Acid) |
Single-family home solar-plus-storage with backup |
|
VT-RHB-HV Series |
5 kW – 20 kW |
Three-Phase |
Hybrid |
High-Voltage (150V – 600V LiFePO4) |
Three-phase high-load residential storage systems |
|
VT-AC Series |
3 kW – 6 kW |
Single-Phase |
AC-Coupled |
Low-Voltage & High-Voltage Options |
Battery retrofits for existing PV installations |
|
VT-OFF Series |
3 kW – 10 kW |
Single-Phase / Split-Phase |
Off-Grid |
Low-Voltage (48V) |
Off-grid residences, remote sites, and cabins |
How to Select the Right Household Inverter
Select the inverter according to the PV system architecture, battery configuration, grid connection, and backup requirements.
|
Grid-tied PV without battery |
VT-RGT Series |
|
PV + 48V battery storage |
VT-RHB-LV Series |
|
Three-phase PV + high-voltage battery storage |
VT-RHB-HV Series |
|
Battery retrofit for an existing PV system |
VT-AC Series |
|
Standalone residential power systems |
VT-OFF Series |
Household Inverter Model Comparison
|
Specification |
VT-RGT Series (On-Grid) |
VT-RHB-LV Series (Hybrid) |
VT-RHB-HV Series (Hybrid) |
VT-AC Series (AC-Coupled) |
VT-OFF Series (Off-Grid) |
|
Rated Power Range |
1 kW – 20 kW |
3.6 kW – 12 kW |
5 kW – 20 kW |
3 kW – 6 kW |
3 kW – 10 kW |
|
Phase Options |
Single / Three-Phase |
Single-Phase |
Three-Phase |
Single-Phase |
Single / Split-Phase |
|
Battery Voltage |
Not Applicable |
Low-Voltage (48V) |
High-Voltage (150V – 600V) |
Low / High-Voltage |
Low-Voltage (48V) |
|
Max. Efficiency |
Up to 98.4% |
Up to 97.6% |
Up to 98.2% |
Up to 97.0% |
Up to 93.5% |
|
Transfer Time |
N/A |
< 10 ms |
< 10 ms |
< 10 ms |
< 20 ms |
|
Parallel Capability |
Up to 10 units |
Up to 10 units |
Up to 10 units |
Up to 6 units |
Up to 6 units |
|
Enclosure Rating |
IP65 / IP66 |
IP65 |
IP65 |
IP65 |
IP20 / IP21 (Indoor) |
|
Cooling Method |
Natural / Fan |
Natural / Fan |
Smart Fan |
Natural |
Smart Fan |
Residential Inverter Types
Grid-Tied Inverters
Convert PV-generated DC power into AC power for residential loads and grid export. Battery storage is not supported in the standard grid-tied configuration.
Hybrid Inverters
Combine PV generation, battery charging and discharging, grid connection, and backup power in one system.
AC-Coupled Inverters
Add battery storage to an existing AC-side PV system without replacing the existing PV inverter, subject to system and communication compatibility.
Off-Grid Inverters
Operate without a utility grid and manage PV generation, battery storage, loads, and auxiliary generators where supported.
Maximum PV Input Voltage: Up to 550V DC for selected single-phase models and up to 1000V DC for selected three-phase models. Refer to the individual datasheet for the applicable model.
MPPT Quantity: 1–4 independent MPPTs are available depending on model, allowing separate PV strings to be managed under different roof orientations or shading conditions.
MPPT Voltage Range: The operating MPPT voltage range varies by model. Refer to the model-specific datasheet for minimum startup voltage, MPPT operating range, and maximum PV voltage.
Maximum PV Input Current: Up to 16A per MPPT on selected models. Maximum short-circuit current varies by model. Check the datasheet before selecting PV modules with high operating or short-circuit current.
PV Oversizing: Selected models support DC/AC ratios up to 150%, subject to the maximum PV input power and voltage/current limits of each model.

Battery Compatibility & Communication
Battery compatibility depends on battery voltage range, maximum charge/discharge current, communication protocol, and BMS requirements.
Low-Voltage Models
Support compatible 48V battery systems, including LiFePO4 and other supported battery chemistries.
High-Voltage Models
Support compatible high-voltage LiFePO4 battery systems within the specified operating voltage range.
BMS Communication
CAN and RS485 communication are available on selected models. Battery communication parameters must be confirmed before system integration.
Battery Compatibility
Provide the battery brand, model, nominal voltage, operating voltage range, and communication protocol when requesting compatibility confirmation.

Before selecting an inverter, confirm the following system parameters:
- PV array power and maximum open-circuit voltage
- PV string operating current and short-circuit current
- Residential grid voltage and frequency
- Single-phase, three-phase, or split-phase configuration
- Battery voltage and maximum charge/discharge current
- Battery BMS communication protocol
- Required backup load and peak load
- Export limitation requirements
- Local grid-code and certification requirements
Safety & Protection
DC Protection
Reverse-polarity protection and insulation monitoring are available according to model configuration.
01
AC Protection
Overcurrent, short-circuit, and anti-islanding protection are provided according to applicable model and grid requirements.
02
AFCI
DC arc-fault detection is available on selected models.
03
Surge Protection
Type II AC and DC surge protection is available on selected models.
04
Protection Configuration
Protection functions and ratings vary by model. Refer to the applicable datasheet and certification documentation for detailed specifications.
05
Installation
Enclosure Rating
Outdoor hybrid and grid-tied models feature IP65- or IP66-rated enclosures. Indoor off-grid models feature IP20- or IP21-rated enclosures.
Operating Temperature
-25°C to 60°C, with output derating above the specified temperature threshold. Refer to the model datasheet for the derating curve.
Parallel Operation
Selected models support multi-unit parallel operation for system capacity expansion via dedicated communication links.
Installation Location
Confirm wall-mounting or floor-mounting requirements, clearance around the inverter, ventilation conditions, cable routing, and ambient temperature before installation.
Grid-Code Pre-Configuration:
Factory-level pre-setting of voltage, frequency, and anti-islanding parameters for specific national grid standards.
BMS Protocol Integration:
Custom CAN/RS485 communication development to integrate non-standard or proprietary lithium battery protocols.
Custom Control Logic
Modification of charge/discharge priority profiles, generator auto-start thresholds, or zero-export response behaviors.
Private Labeling & Branding
Custom silkscreen printing, laser-etched brand logos, customized rating plates, and unique serial number sequencing.
Port & Interface Modifications
Optional hardware modules including integrated DC switches, external Wi-Fi/4G dongle enclosures, or customized terminal block configurations.
FAQ
As one of the most professional household inverter manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please rest assured to wholesale advanced household inverter at competitive price from our factory.