Commercial Solar Inverters for C&I Applications
Commercial solar inverters convert DC power from PV arrays into three-phase AC power for commercial and industrial (C&I) facilities. Available as string and hybrid configurations, they support commercial rooftops, industrial facilities, carports, and solar-plus-storage systems on 380/400V three-phase grids.
Product Range
C&I String Solar Inverters
Three-phase grid-tied string inverters engineered for commercial rooftop installations, industrial facilities, and ground-mounted solar projects.
Commercial Hybrid Solar Inverters
Bi-directional three-phase inverters designed to manage concurrent solar PV generation and battery storage charge/discharge cycles for C&I applications.
Solar-Storage-Charging Integrated Inverters
Multi-functional power conversion units built for commercial EV charging hubs and microgrid architectures requiring combined PV generation, energy storage, and EV load management.
C&I Inverter Model Selection
|
Parameter |
Available Range |
|
Rated Power |
15–185 kW |
|
Grid Type |
Three-phase |
|
Grid Voltage |
380/400 V |
|
Frequency |
50/60 Hz |
|
Max. PV Voltage |
Up to 1000/1100 V |
|
MPPT Channels |
2–12 |
|
Max. MPPT Current |
Up to 45 A |
|
Max. DC/AC Ratio |
Up to 150% |
|
Max. Efficiency |
Up to 98.6% |
|
Protection Rating |
IP65/IP66 |
Inverter Power
|
Power Class |
Typical Application |
Parallel Capability |
|
15–20 kW |
Small commercial buildings, offices, retail sites |
Model dependent |
|
25–50 kW |
Warehouses, logistics centers, medium industrial facilities |
Model dependent |
|
55–125 kW |
Manufacturing plants, industrial parks, commercial carports |
Model dependent |
|
150–185 kW |
Large C&I PV and ground-mounted systems |
Model dependent |
MPPT Quantity: Configured with 2 to 12 independent MPPT channels depending on unit power class to optimize energy yield across complex roof layouts.
Maximum Input Current: Supports high-current PV modules with MPPT input current ratings up to 45A per tracker.
DC/AC Oversizing Ratio: Up to 150% on selected models, subject to model-specific design limits.
MPPT Voltage Range: Model-dependent operating voltage ranges support PV string configurations up to 1000/1100 V maximum DC voltage.
Maximum DC Voltage: Designed with maximum DC input voltage ratings up to 1000V or 1100V to support extended string lengths.

Grid Compatibility
Grid Voltage & Frequency
Three-phase 380/400 V systems at 50/60 Hz, depending on model and market configuration.
Power Factor Control
Adjustable power factor range from 0.8 leading to 0.8 lagging to satisfy utility grid voltage regulation and reactive power requirements.
Grid-Code Compliance
Grid-code configurations are available for applicable markets, including VDE-AR-N 4105/4110, EN 50549, and AS/NZS 4777.
Efficiency & Thermal Management
Conversion Efficiency
Maximum efficiency reaches up to 98.6%, with European-weighted efficiency up to 98.4% on selected high-power string models.
Smart Air Cooling
Temperature-controlled variable-speed cooling systems adapt airflow rates based on real-time internal power module temperatures.
Thermal Management
Automatic power derating protects inverter operation under high ambient temperatures.
Standby Self-Consumption
Night-time standby power draw is maintained below 3.5 W to minimize auxiliary energy consumption when the system is inactive.
Protection & Durability
Enclosure Protection
IP65 or IP66 depending on model, supporting outdoor installation where specified.
DC Arc Fault Protection (AFCI)
Available on applicable models to detect abnormal DC arcing and initiate automated circuit interruption.
Surge Protection Devices (SPD)
Equipped with integrated Type II AC and DC surge arresters to isolate sensitive components from switching transients and indirect lightning strikes.
Electrical Safety Protection
Includes DC reverse-polarity, AC short-circuit, overcurrent, overvoltage, and insulation monitoring functions, depending on model.

Communication Hardware: Built-in RS485 and Ethernet connections, with optional WLAN or 4G/5G cellular modems for remote telemetry.
Protocol Compatibility: Supports standard Modbus RTU / Modbus TCP protocols for integration into third-party Energy Management Systems (EMS) and Supervisory Control and Data Acquisition (SCADA) platforms.
Smart IV Curve Diagnosis: Supports automated or on-demand string-level IV curve scanning to detect module degradation, open circuits, or localized shading without manual field testing.
Remote Management: Remote monitoring, parameter configuration, firmware updates, and fault alarm management.
Supplier Capabilities
Manufacturing Infrastructure
Self-owned production facilities equipped with automated assembly systems, circuit testing equipment, and specialized inverter burn-in test bays.
R&D and Engineering Team
In-house engineers covering power electronics, inverter control, grid integration, and EMS communication.
System Integration
Pre-matched equipment packages combining PV inverters, mounting accessories, energy storage systems, and monitoring hardware.
Quality Assurance
Incoming component inspection, insulation testing, functional testing, thermal testing, and full-load testing are performed according to defined production procedures.
FAQ
As one of the most professional commercial inverters manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please rest assured to wholesale advanced commercial inverters at competitive price from our factory.








